Output Power |
>500W |
Output Type |
Single |
Type |
DC/AC Inverters |
Introduction
This street light controller is specially designed for wind & solar hybrid energy street lamp system. The device is able to offer perfect running performances and convenient operations, it not only controls the battery charging, but also controls the street light open and close automatically through solar light + time controlling. It is adopted the constant voltage charging with PWM method and has reliable and safe operation, high efficiency, life-service providing.
Features 1. This product has the function of electronic brake and electronic resistor, getting rid of mechanical fault. 2. Resistor and controller design diverging, against high temperature influence battery and controller. 3. The resistor can open circuit inspection and automatic protection design. 4. The battery charge and discharge uses the intelligent display technology, the battery uses the intellectual management and the charge temperature compensation (it has the automatic identification of temperature sensor on-line function) 5. The battery works under average charge mode (automatically exchange between quick charge and floating charge) 6. It has the converse charge protection, the over charge and discharge protection, the over voltage protection, the over heat protection, over load and short-circuit protection and the charge converse connection protection. 7. The system has over voltage and low voltage quakeproof design, which guarantees the system stability. 8. The system has the sunlight control and time control output, or the sunlight and time hybrid control output. 9. Optimal stable system technical design, the wind turbine generator rotational speed, output voltage, current, and output power use the flexible control technology, the system has realized the precise power distribution and the wind generator assistant start function and abnormal protection.
Specifications and technical date sheet
|
Model
|
SW 03-12
|
SW
03-24
|
SW
04-12
|
SW
04-24
|
SW
05-12
|
SW
05-24
|
SW
06-12
|
SW
06-24
|
|
Wind turbine rated power ( W)
|
300
|
300
|
400
|
400
|
500
|
500
|
600
|
600
|
|
Wind turbine Rated voltage (V)
|
12
|
24
|
12
|
24
|
12
|
24
|
12
|
24
|
|
Solar Max Power (W)
|
100
|
100
|
150
|
150
|
150
|
150
|
200
|
200
|
|
Rated Battery Voltage ( V)
|
12
|
24
|
12
|
24
|
12
|
24
|
12
|
24
|
|
Over-charge Voltage (V)
|
14.5
|
28.8
|
14.5
|
28.8
|
14.5
|
28.8
|
14.5
|
28.8
|
|
Over-chargevoltage recovery (V)
|
14
|
26.8
|
14
|
26.8
|
14
|
26.8
|
14
|
26.8
|
|
Over-discharge Voltage ( V)
|
10.8
|
21.6
|
10.8
|
21.6
|
10.8
|
21.6
|
10.8
|
21.6
|
|
Over-discharge Recovery Voltage ( V)
|
12
|
24.6
|
12
|
24.6
|
12
|
24.6
|
12
|
24.6
|
|
LCD Display
|
Battery voltage, charge current, running status
|
|
Protection type
|
Over-charge voltage, Over-discharge voltage, Over load, Short circuit, High-hot, Pole reverse connection
|
|
Operation Ambient Temperature
|
-10
???/span>~60???/span>
|
|
Operation Ambient Humidity
|
0~90%, no condensing
|
|
Dimension( L x W x H )
|
175 x 150 x 70 mm
|
|
Weight
|
1.2Kg
|
|